VS-Q262 - Thiết bị lập trình điều khiển- PLC Module Converter
Xuất sứ: Japan
Nhà cung cấp: NSD
Hãng sản xuất: NSD Corp
Ứng dụng sản phẩm: Ngành Dệt, Ngành Thép, Ngành Thực Phẩm, Ngành Xi Măng
NSD GROUP - Sản Phẩm Được Phân Phối Độc Quyền Bởi
SONG THÀNH CÔNG

VS-Q262
VS-Q262 is NSD smart PLC built-in controller for MELSEC-Q series with 2 sensor channels.
Model coding
VS-Q262-[1]
[1]Applicable sensor
| Code | Applicable sensor |
|---|---|
| M2PG | MRE-32SP062/MRE-G□SP062(□ : 64/128/160/256/320) |
| L | VLS-256PWB/VLS-512PWB/VLS-1024PW |
Contact us about other specifications.
Applicable System
| Programmable controller CPU |
Q00JCPU | Q00CPU | Q01CPU | Q02CPU | Q02HCPU | Q06HCPU |
|---|---|---|---|---|---|---|
| Q12HCPU | Q25HCPU | Q02PHCPU | Q06PHCPU | Q12PHCPU | Q25PHCPU | |
| Q12PRHCPU | Q25PRHCPU | Q00UJCPU | Q00UCPU | Q01UCPU | Q02UCPU | |
| Q03UDCPU | Q04UDHCPU | Q06UDHCPU | Q10UDHCPU | Q13UDHCPU | Q20UDHCPU | |
| Q26UDHCPU | Q03UDECPU | Q04UDEHCPU | Q06UDEHCPU | Q10UDEHCPU | Q13UDEHCPU | |
| Q20UDEHCPU | Q26UDEHCPU | Q50UDEHCPU | Q100UDEHCPU | Q03UDVCPU | Q04UDVCPU | |
| Q06UDVCPU | Q13UDVCPU | Q26UDVCPU | Q06CCPU-V | Q06CCPU-V-B | Q12DCCPU-V | |
| Q24DHCCPU-V | Q24DHCCPU-LS | |||||
| Q01WCPU-W1-J | Q01WCPU-W1-CF-J | Q01WCPU-W1-E | ||||
| Q01WCPU-W1-CF-E | PPC-100-DC5511 | PPC-100-DC5311 | ||||
| Remoto I/O module |
QJ72LP25-25 | QJ72LP25G | Q72BR15 | |||
ABSOCODER Basic Configuration

Specification
General specification
| Item | Specification | ||||
|---|---|---|---|---|---|
| Ambient operating temperature | 0 ~ +55℃ (No condensation or freezing) | ||||
| Vibration resistance | Conforms to JIS B3502 and IEC 61131-2 | Under intermittent vibration conditions | Sweep count | ||
| Frequency | Acceleration | Amplitude |
10 times in 3 direction (X, Y, Z) (for 80 min) |
||
| 10 ~ 57Hz | - | 0.075mm | |||
| 57 ~ 150Hz | 9.8m/s2(1G) | - | |||
| Under continuous vibration conditions | |||||
| Frequency | Acceleration | Amplitude | |||
| 10 ~ 57Hz | - | 0.035mm | |||
| 57 ~ 150Hz | 4.9m/s2(0.5G) | - | |||
| Shock resistance | Conforms to JIS B3502 and IEC 61131-2 (147 m/s2 (15G), 3 times in 3 direction (X, Y, Z)) | ||||
| Operating ambience | Free of corrosive gases | ||||
| Operating height | 2000m or less | ||||
| Over voltage category | 2 or less | ||||
| Contamination level | 2 or less | ||||
| Internal power consumption | 0.7 A (5 VDC) | ||||
| Mass | 0.2kg | ||||
Performance Specification
| Item | Specification | |||
|---|---|---|---|---|
| Converter model | VS-Q262-M2PG | VS-Q262-L | ||
| Applicable sensor | MRE-32SP062 | MRE-G□SP062 | VLS-□PW | |
| Position detection format | Absolute position detection | |||
| Number of divisions | 4096 Divisions×32 Turns to 409.6 Divisions×320 Turns |
256 ~ 1024mm/65536 Divisions | ||
| Number of detection axes | 2 | |||
| Data setting method | PLC CPU program | |||
| Positioning function | Control format | Unidirectional positioning or Bidirectional positioning | ||
| Control output |
Forward (FWD), Reverse (RVS), High-speed, Low-speed, Brake release, In-position, Positioning in progress, Operation error |
|||
| Switch output function |
Number of programs | 9 | ||
| Number of switch outputs | For switch output function only: 8 points | |||
| Number of multi-dogs | 10 times for each switch output | |||
| Position data sampling time |
Switch output Positioning output |
1.6ms | ||
| Current position output | 0.8ms | |||
| Response time | Switch output Positioning output |
3.2ms | ||
| Current position output | 1.6ms | |||
| Number of I/O points occupied | 32 points (I/O assignment: intelligent) | |||
| Setting value memory | Non-volatile memories | |||
| Auxiliary functions |
Current position detection, positioning function, switch outputs, current position preset, JOG operation, |
|||
| Max. sensor cable length |
Standard | 100m | 100m | 100m |
| Robotic(RBT) | 40m | 70m | 50m | |